Direct answer: At 3,000 m, barometric pressure falls to about 70 kPa, so 20°C air weighs roughly 0.83 kg/m³ — 69% of the 1.2 kg/m³ standard air used on fan curves. The fan still moves the same actual m³/h, but builds only 69% of its catalog pressure and absorbs 69% of its catalog power. Correct sizing takes two steps: select at site pressure × 1.45 on the standard-air curve, then divide site shaft power by the motor’s altitude factor (about 0.86 at 3,000 m).
Two Corrections, Not One
Altitude affects a blower installation in two separate ways. The first is aerodynamic. A centrifugal fan is a constant-volume machine: at a given speed it moves the same actual cubic meters per hour whatever the air density, but the pressure it develops and the power it absorbs both scale directly with density. Thinner air means less pressure and less power from the same wheel.
The second is thermal. The motor is cooled by that same thin air, so it sheds heat less effectively and can no longer deliver its full nameplate output continuously. Standard motor ratings assume an installation at or below 1,000 m.
A sound blower altitude correction handles both effects, separately and once each. Most sizing errors on high-altitude sites come from applying only one of them, or applying the density correction twice. This is not a niche problem: Mexico City sits at about 2,240 m, Bogotá at about 2,640 m, Quito at about 2,850 m, and many mines and concentrators in the Andes of Peru, Chile and Bolivia operate between 3,000 and 4,500 m.
Air Density and Motor Derating by Altitude
The table gives both factors at common site elevations. Density is shown for 20°C air, so it compares directly with the 1.2 kg/m³ standard air behind fan catalog curves.
| Altitude (m) | Barometric Pressure (kPa) | Air Density at 20°C (kg/m³) | Density Ratio vs. Sea Level | Catalog Pressure Multiplier* | Typical Motor Derating Factor** |
| 0 | 101.3 | 1.20 | 1.00 | 1.00 | 1.00 |
| 1,000 | 89.9 | 1.07 | 0.89 | 1.13 | 1.00 |
| 1,500 | 84.6 | 1.00 | 0.83 | 1.20 | 0.97 |
| 2,000 | 79.5 | 0.94 | 0.78 | 1.27 | 0.94 |
| 2,500 | 74.7 | 0.89 | 0.74 | 1.36 | 0.90 |
| 3,000 | 70.1 | 0.83 | 0.69 | 1.45 | 0.86 |
| 3,500 | 65.8 | 0.78 | 0.65 | 1.54 | 0.82 |
| 4,000 | 61.6 | 0.73 | 0.61 | 1.64 | 0.77 |
* Multiply the required site pressure by this factor to get the pressure to select on a standard-air fan curve (site air at 20°C). Barometric pressure is from the International Standard Atmosphere model; correct further for your actual design temperature.
** Typical continuous-output factors for low-voltage TEFC motors at 30–40°C ambient, from published manufacturer data (e.g., Siemens). Values vary by manufacturer and insulation class, and a cooler site can partly offset the derating — always confirm against the motor supplier’s own altitude-temperature table.
Step-by-Step: Sizing a Blower for a 3,000 m Site
Worked example: an exhaust blower for a mineral processing plant at 3,000 m, handling 30,000 m³/h of actual air at 3,000 Pa total pressure, 20°C, with an assumed fan efficiency of 80%.
- Define the duty in actual site terms. You need flow in actual m³/h at the fan inlet, pressure in Pa at site conditions, the site altitude and the design air or gas temperature. If the process gives flow in Nm³/h, convert it first (see the first mistake below).
- Calculate site air density. ρ_site = 1.20 × (p_site ÷ 101.3) × (293 ÷ (273 + t)). Example: 1.20 × (70.1 ÷ 101.3) × 1.0 = 0.83 kg/m³, a density ratio of 0.69.
- Convert site pressure to a standard-air selection pressure. Δp_std = Δp_site ÷ density ratio. Example: 3,000 ÷ 0.69 ≈ 4,350 Pa (or 3,000 × 1.45 from the table). Select the fan that delivers 30,000 m³/h at about 4,350 Pa on its standard-air curve — that is the wheel size and speed that will actually make 3,000 Pa in thin air.
- Calculate shaft power at site density. P_site = Q × Δp_site ÷ η. Example: (30,000 ÷ 3,600) × 3,000 ÷ 0.80 ≈ 31 kW. The standard-air curve will show about 45 kW at the same point — that is what the fan would absorb at sea level, not what it absorbs on site.
- Size the motor with the altitude derating. Motor rating = P_site × service margin ÷ altitude factor. Example: 31.3 × 1.15 ÷ 0.86 ≈ 42 kW, so a 45 kW motor. Without derating, the same duty points to a 37 kW motor, which would run hot continuously at 3,000 m.
Three Common Mistakes on High-Altitude Projects
- Treating Nm³/h as actual flow. Normal cubic meters are referenced to 0°C and 101.325 kPa. At 3,000 m and 20°C, 30,000 Nm³/h is about 46,500 m³/h of actual volume at the fan inlet — roughly 55% more. A fan sized on the Nm³/h figure runs short of flow from day one.
- Correcting a pressure that is already on a standard-air basis. Duct and equipment losses scale with density. If the system resistance was calculated with 1.2 kg/m³ air, that number already is the standard-air selection pressure. Multiplying it by 1.45 again oversizes both the fan and the motor.
- Running the shop test at full speed on sea-level air. A fan selected for 3,000 m absorbs about 1.45 times its site power when tested at sea level. In the example above, that is about 45 kW on a 45 kW motor, with no margin left. Test at reduced speed or with the inlet throttled, then convert the results to site density with the fan laws.
For medium-voltage motors, starters and switchgear above 1,000 m, also confirm insulation and clearance ratings for altitude. Thin air lowers dielectric strength as well as cooling.
What to Send for an Accurate High-Altitude Selection
A high-altitude selection is only as good as the site data behind it. The essentials are:
- Site altitude, plus minimum and maximum design ambient temperature
- Flow, and whether it is actual m³/h or Nm³/h
- Required pressure, and whether it was calculated at site or standard density
- Gas composition and temperature, if it is not ambient air
- Motor voltage, frequency and any enclosure or explosion-protection requirement
Running a project above 1,500 m? Submit your specs here and our engineering team will return a performance curve at your actual site density, with the motor sized for altitude derating — not a sea-level catalog rating.