Y8-39/Y9-38 Induced Draft Fan for Boilers

Impeller diameter: 400~1600 mm

Speed of main shaft: 730~2900 r/min

Pressure range: 1157~5805 Pa

Flow range: 3242~110666 m3/h

Share:

Description

This blower applies to 0.5-35t/h industrial boilers equipped with economizer (pre-heating device) and dust removal devices. All industrial boilers with similar inlet conditions and right performance can use such blowers. But the air inlet temperature may not exceed 250℃.

Dust removal device with de-dusting efficiency of not lower than 85% shall be installed before induced draft fans to minimize the dust content entering blowers. This not only reduces environmental pollution, but also lower blower wearing caused by dust, improving blowers’ service life.

Key Advantages

  • Impellers- They are composed of long and short front-curved Q345 (16Mn) blades. After static and dynamic balance correction, this blower enjoys stable operation.
  • Casing-It is a volute casing made of welded steel plates. It has a dust cleaning door, which is easy for workers to remove the dust fallen on impellers and inside blower casing and thus ensures impellers’ balance and aerodynamic performance.
  • Air inlet- With convergent and streamlined integrated design, the air inlet is fixed to front cover plate with screws.
  • Air damper-The air damper has petal-design blades and are axially mounted before the air inlet. Fans with No. 4-6.3 have 9 blades for air dampers while fans with No. 8 and upper series have 11 blades for air dampers. Thanks to the outside driving structure, they enjoy flexible and easy rotation. The adjusting range is from 0° (fully open) to 90° (fully closed). Looking from the side of the air inlet, the handle of the air damper is on the right side. For right rotation blowers, the handle moves from fully closed to fully open by moving from bottom to top. For left rotation blowers, the handle moves from fully closed to fully open by moving from top to bottom. Air damper has to be lubricated carefully to ensure its normal operation. Blowers apply temperature-resistant (260℃) lubrication grease for lubrication, ensuring good lubrication under high temperature operation.
  • Driving system-The driving system consists of main shaft, water cooling bearing box and coupling, etc. The main shaft is made of quality steel and the bearing is rolling bearing. The bearing box has both integrated type and separate type. Blowers with No.4~No.6.3 apply integrated type bearing box while blowers with No.4~No.6.3 apply water cooling integrated bearing box. Both bearing boxes need cooling water; water consumption varies with ambient temperature and is usually considered as 0.5-1m3/h. Equipped with thermometer and oil level indicator, the bearing box uses L-AN46 (Lubricating Oils for Total Loss Systems L-AN). The oil amount to be added shall be based on the oil level indicator.

Specification

Item nameY8-39/Y9-38 Induced Draft Fan for Boilers
Parts detailsImpeller diameter400~1600mm
Speed of main shaft730~2900r/min
Pressure range1157~5805Pa
Flow range3242~110666m3/h
StructureBlade structureForward
Impeller supportSingle support
DrivetrainC/DAssignable
LubricationOil bath lubrication / grease lubricationAssignable
Bearing coolingCirculation water cooling/air cooling 
Circulation oil cooling 
System
configurationMotorAnhui Wannan, Lu’an Jianghuai, Henan Yutong, Jiamusi, Nanyang Explosion Proof, Siemens 
Impeller, air inlet, blower casing, air damperCarbon steelCustomizable
Main shaftHigh strength carbon structure
BearingFAG, SKF, ZWZ, C&U,YLC…
Bearing boxCasting iron 
DrivetrainCoupling/ belt pulleyAssignable
Foundation boltCarbon steel 
Optional
partsSystem base frame, Protective screening, Silencer, Inlet& outlet pipeline compensator, Inlet& outlet flange, Air damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Variable-frequency drive, Special motor, System monitoring &control instrument, Lubrication system and High-level oil tank.

Application

They are applicable to normal temperature and hot gas, clean and dusty gas, powder materials and tiny granules. They can apply into boilers, dust removal, de-nitration and desulfurization, cement, metallurgy, power generation, gas and material handling, smoke exhausting. It can also be customized according to special industries.

Get In Touch With Us

If you are interested in our products, please feel free to contact us, and you are welcome to visit the factory for more product details